日立GVF-III调试手册

2021/7/24 13:41:49点击:

日立GVF-III调试手册

GVF-Ⅲ电梯安装调试手册

前 言
本资料介绍 GVF-Ⅲ型电梯,该梯种以集成了变频控制和逻辑控制的 EV-ECD 01(MCUB)
控制板、SCL 串行通讯系统和 RD-DMS01 变频门机系统作为电气的关键组成部分,并基本使
用了 GVF-Ⅱ型电梯的机械系统。
资料编写目的:随着 GVF-Ⅲ电梯的开发成功,在工程方面需要提供安装、调试、维
修和保养各项工作的技术说明。本资料是根据 GVF-Ⅲ电梯的技术特点,列出电梯在工程环
节中所需使用的资料,为工程本部编写 GVF-Ⅲ电梯工程技术资料提供依据。由于 GVF-Ⅲ
电梯在电气控制原理上与 GVF-Ⅱ电梯有较多的相同点,又基本使用 GVF-Ⅱ电梯的机械系
统,所以本资料对于相同点不再进行叙述,只作出说明“与 XX 电梯保持一致”。
本资料基本内容:
(1) GVF-Ⅲ电梯构成和技术特点。
(2) 安装部分。电气回路图的使用说明;控制柜及轿顶电器箱等重要电气部分的名
称、功能介绍;工程大、细线及地线的安装。
(3) 调试部分。运行前需进行检查的电梯各项安装情况,控制柜绝缘测试、低速试
运行、变频门机的调试运行、层高测定操作、高速运行调试、平层精度调整等。
如有修改意见,请填写附页的《GVF-Ⅲ电梯调试手册改进意见表》(复印有效),传真
或直接交由工程本部工程技术科以作修改。

目 录
一.GVF-Ⅲ电梯的技术概述··············································5
 1.技术构成及特点··················································5
 2.GVF-Ⅱ与 GVF-Ⅲ的简单比较········································6
 2.1 机械部分的不同点············································6
 2.2 电气方面不同部分的简单比较···································7
 3.GVF-Ⅲ电梯的规格················································8
二.GVF-Ⅲ电梯机械部分的安装···········································8
三.GVF-Ⅲ电梯电气部分的安装···········································8
 1.电气回路图的说明·················································8
 1.1 电气回路图的类别和内容·······································8
 1.2 控制柜对外的接线代号及用途···································9
 1.3 电气回路图的读图方法·········································9
 2.电梯电源参数····················································11
 3.控制柜概要······················································12
 3.1 控制柜尺寸及主要部件的安装图·································12
 3.2 控制柜内部主要部件的名称和功能·······························14
 4.轿顶电器箱元件布置图············································15
5.井道内器件、电缆的安装··········································16
 5.1 井道内器件的安装与接线······································16
 5.2 井道内电缆的安装············································16
 6. 厅外召唤箱的安装、接线及 DIP 开关的设置·························17
 7. 接地线作业·····················································17
 7.1 控制柜内接地线回路图········································17
 7.2 系统地线敷线图··············································18
 8. 其他敷线························································18
四.运行调试···························································19
 1. 运行前准备······················································19
 1.1 运行前检查·····················································19
1.2 控制柜绝缘测试·················································19
 1.2.1 准备工作··················································19



标记 处数
 1.2.2 测试方法··················································19
 1.2.3 各回路绝缘标准阻值········································20
 1.3 电压测试························································21
 1.4 混杂电压检查····················································21
 2. 变频门机的调整···················································22
 2.1 机械调整························································22
 2.2 电气系统介绍····················································24
 3. 低速试运行······················································26
3.1 开始低速运行····················································26
 3.1.1 通电前准备·················································26
 3.1.2 通电低速试运行·············································26
 3.2 安全回路的确认··················································27
3.3 变频门机的门宽自检测············································27
 3.4 变频门机开关门速度的调整········································27
 3.5 变频门机的故障检出··············································28
 4. 高速试运行前检查和调整··········································28
 5. 高速试运行······················································29
5.1 层高测定························································29
 5.1.1 层高测定运行前的确定······································29
 5.1.2 层高测定的操作顺序········································29
 5.2 层高测定前后的软件确认··········································29
 5.3 高速试运行······················································30
 5.4 电梯对重配置····················································30
5.5 平层调整························································30
 5.6 起动补偿调整····················································31
5.7 轿内负荷检测设置···············································31
 6. 起动舒适感调整··················································32
 7. 功能确认························································32
五.MCUB 板使用说明····················································33
 1. MCUB 板简介·····················································33



标记 处数
 2. 小键盘介绍·····················································34
 2.1 硬件介绍·······················································34
 2.2 一般操作·······················································34
 2.3 各状态解释·····················································35
六.艾默生变频器专用操作面板使用说明···································39
1. 操作面板硬件说明················································39
 2. 按键功能说明···················································39
3. 指示说明························································40
4. 键盘操作说明···················································40
 七.手持编程(GHP)操作说明············································42
 1.手持编程(GHP)硬件说明··········································42
 2.按键功能说明·····················································43
 3.GHP 操作流程简介················································44
八.故障说明···························································44
 1.电梯故障的内部处理方式···········································44
 2.电梯故障代码表···················································45
 3.变频器故障代码表·················································46


文件下载:点击下载日立GVF-III调试手册 (点击查看下载口令
    下载申明:(1)六台盒宝典资料大全2024梯控提供的日立GVF-III调试手册资料来源于网络收集整理,并免费提供下载日立GVF-III调试手册不收取任何费用,若发现您的权益受到侵害,请立即联系我们,我们会立即删除日立GVF-III调试手册资料。(2)六台盒宝典资料大全2024梯控提供的日立GVF-III调试手册资料仅供用户学习和参考,用户如果使用下载的日立GVF-III调试手册资料造成任何损失与六台盒宝典资料大全2024无关,日立GVF-III调试手册资料最终以版权厂家提供原厂资料为准。(3)六台盒宝典资料大全2024梯控免费提供大量日立电梯技术资料下载,欢迎收藏本站,底部右下角提供了搜索功能,六台盒宝典资料大全2024人脸识别梯控、IC刷卡梯控、二维码梯控、指纹识别梯控、语音梯控、CPU梯控、ID卡梯控、手机乘梯、机器人乘梯等广泛应用于日立电梯,欢迎扫码二维码加个微信咨询或备用,再次感谢您在六台盒宝典资料大全2024梯控免费下载日立电梯日立GVF-III调试手册。